Vcehome > Oracle > Oracle Utilities Customer Cloud > 1Z0-996-22 > 1Z0-996-22 Online Practice Questions and Answers

1Z0-996-22 Online Practice Questions and Answers

Questions 4

Your client has installed scalar devices to measure the solar energy generated (Export) and the energy received (Import) from the National Grid. This data is stored in separate measuring components (registers).

The validation rules are generally the same for both measuring components, but there is one exception. The Negative Consumption check applies only to energy received (import). Which two are possible configurations resulting in the Negative Consumption rule being checked for energy received (import) only? (Choose two.)

A. Modify the base VEE rule.

B. Remove the Negative Consumption check from the VEE group.

C. Create two different VEE groups.

D. Use Eligibility Criteria.

E. Use the Skip Flag in the VEE rule.

Browse 70 Q&As
Questions 5

If a customer makes a payment for more than what is due for the account, which entity contains the logic for how this overpayment should be handled?

A. Tender Type

B. Installation Options

C. Customer Class

D. Pay Segment Type

E. Service Agreement Type

Browse 70 Q&As
Questions 6

How many service agreements are linked to a severance process?

A. all service agreements that are connected to the initiating overdue process

B. one

C. any number defined by the business user

D. zero - accounts are linked to severance processes

E. all service agreements that are connected to the initiating collection process

Browse 70 Q&As
Questions 7

Which usage rule would be used to retrieve scalar measurements and convert the total from one unit of measure to another?

A. Get Scalar Details and Math

B. Get Scalar Details and Apply Formula

C. A custom set of usage rules must be written.

D. Get Scalar Details and Axis Conversion

Browse 70 Q&As
Questions 8

Which three statements are true about the different types of measuring components? (Choose three.)

A. Seconds-per-interval (SPI) is one of the attributes of scalar measuring components.

B. Only physical measuring components reference a device configuration.

C. The terms register and channel are synonyms for measuring component.

D. The measuring component types are physical, standalone, scratchpad, and TOU.

E. Scalar measuring components contain a single measurement for an arbitrary period of time.

Browse 70 Q&As
Questions 9

Your client has three requirements:

1.

Apply validations on meter reads coming from the Data Collectors.

2.

If a meter read does not pass the validation, an error will be generated and assigned to a user.

3.

Retry the validation every 30 minutes for the errors in case the issue is related to configuration. Which statement describes the base functions you should use?

A. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-COMP-TD (Complete To Do Entries).

B. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-IMD-RETRY (Retry Initial Measurement Data Processing)

C. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be loaded after 30 minutes.

D. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-CRE-IMDTD (Create To Do)

E. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be manually loaded.

Browse 70 Q&As
Questions 10

A device has one or more measuring components that measure consumption, demand, or other values.

Which lists two attributes of a measuring component?

A. Channel Multiplier and Channel ID

B. Channel ID and Badge Number

C. Serial Number and Badge Number

D. Model and Serial Number

E. Manufacturer and Model

Browse 70 Q&As
Questions 11

Your implementation requires an installation of two types of devices:

1.

Electric Smart Meter

2.

Gas Manual Meter

Which two Device Type attributes are required to identify these device types? (Choose two.)

A. Device Business Object

B. Service Type

C. Valid Measuring Component Types

D. Manufacturer

E. Serial Number

Browse 70 Q&As
Questions 12

How many bill segment-related financial transactions do Payment Arrangements have?

A. depends on the number of bills that will contain the customer's payment arrangement details

B. one

C. depends on the number of payments that are part of the payment arrangement

D. unlimited

E. none

Browse 70 Q&As
Questions 13

At what stage in the initial measurement data (IMD) import process will the application of meter multipliers be performed?

A. Critical Validation

B. VEE

C. Prepare for VEE

D. post-VEE

Browse 70 Q&As
Exam Code: 1Z0-996-22
Exam Name: Oracle Utilities Customer Cloud Service 2022 Implementation Professional
Last Update: May 11, 2024
Questions: 70 Q&As

PDF

$49.99

VCE

$59.99

PDF + VCE

$67.99