Vcehome > EMC > EMC Certification > E20-377 > E20-377 Online Practice Questions and Answers

E20-377 Online Practice Questions and Answers

Questions 4

Under which condition will Enquiry remove the Consistency Exempt attribute from the RDF mirror?

A. Deleting RDF pairs

B. Suspending RDF pairs

C. Splitting RDF pairs

D. Creating RDF pairs.

Browse 104 Q&As
Questions 5

Refer to the Exhibit.

Server A and Server B are running two different applications on SRDF R1 devices on the Source

Symmetrix. All the R1 devices belong to the same RDF group. Both applications are replicated with SRDF/

S.

A disaster has occurred at the source site.

Which step is needed to restart the applications at the remote site?

A. Execute SRDF failover for all devices in the RDF group

B. Halt the applications on Server A and B and then execute SRDF failover for all devices in the RDF group

C. Execute SRDF fallback for all devices in the RDF group

D. Shut down Server A and B and then execute SRDF fallback for all devices in the RDF group

Browse 104 Q&As
Questions 6

A customer has implemented a symclone create command with the pre copy option. The clone session was than activated. At this point what is the state of the clone target device?

A. White Dashboard (WD)

B. Read write enabled (RW)

C. Not Ready (NR)

D. Read Only enabled (RO)

Browse 104 Q&As
Questions 7

What is suppressed when scripting SYMCU commands using the -nop option?

A. Confirmation questions to the command screen

B. Informational messages to the command screen

C. Error messages to the command screen

D. All outputs to the command screen

Browse 104 Q&As
Questions 8

After acquiring a company 300 hundred miles from their current office the customer has asked EMC to

help to design a single hop application recovery plan after careful analysis of the work load and available

bandwidth, SRDF/AR was selected as the solution.

If the SRDF/AR cycle time is set to 90 minutes, what is the maximum potential data loss?

A. 2 hours of data

B. 1.5 hours of data

C. 4.5 hours of data

D. 3 hours of data

Browse 104 Q&As
Questions 9

Refer to the Exhibit.

A Symmetrix is configured with the two RDF Groups RDFG 1 and RDFG 2 as shown. The SRDF R1

devices used by Application (App 1) are in RDFG 1. The SRDF R1 devices used by Application 2 (App 2)

are in RDFG 2.

What should be created to allow independent management of SRDF/A sessions for Applications 1 and 2?

A. One device group with all the devices in RDFG 1 and RDFG 2

B. One file with the App 1 and the App 2 devices

C. Two device groups, one with the App 1 devices and another with the App 2 devices

D. One composite group with all the devices in RDFG 1 and RDFG 2

Browse 104 Q&As
Questions 10

What is required when the symdev list command shows the TEMEVs (?!) are in a Not Ready state?

A. Must be part of the default pool

B. Must be mapped to a front-end port

C. Must create an extent that is 12 tracks

D. Must be bound to a thin pool

Browse 104 Q&As
Questions 11

Open Replicator will be used to move data from a Symmetrix V-max array to a CLARiiON array. The CLARiiON array has NOT been discovered by the host on which Open Replicator commands are issued. Which information has to be specified in the Open Replicator device File?

A. Symdev=arrayid device clardev=arrayid: CLARiiON device WWN

B. symdev=arrayed:device www=CLARiiON device WWN

C. symdev= arrayid device clardev=arrayid device

D. wwn=Symmetrix device WWN WWN=CLARiiON device WWN

Browse 104 Q&As
Questions 12

A customer wants to implement incremental Open Replicator. What is a valid operation?

A. Incremental Hot Pull

B. Restore of Incremental Hot Pull

C. Incremental Cold Push

D. Restore of Incremental Cold Pull

Browse 104 Q&As
Questions 13

One of the requirements during an Open Replicator implementation is to provide all available resources to Open Replicator. How should the Pace and Ceiling values be configured?

A. Pace and Ceiling should be left at the default.

B. Pace should be set to 0 and Ceiling set to 100.

C. Pace should be set to 9 and Ceiling set to 0.

D. Pace should be set to 9 and Ceiling set to NONE.

Browse 104 Q&As
Exam Code: E20-377
Exam Name: RecoverPoint/SE Specialist Exam for Implementation Engineers
Last Update: May 08, 2024
Questions: 104 Q&As

PDF

$49.99

VCE

$59.99

PDF + VCE

$67.99