DRAG DROP
In the Answer Area, drag each use case on the left to the correct Toolbox item.
Select and Place:
DRAG DROP
Pega Robot Studio has several methods to manage the flow of an automation depending on when a control is matched. In the Answer Area, drag the description on the left to its matching Design Block.
Select and Place:
DRAG DROP
When interrogating a Windows control, the drag and drop Default interrogation method does not work. You decide to use the Create Control option to interrogate the control. From the Interrogation Steps list, move all of the options to the Ordered Interrogation Steps column and place them in the correct order.
Select and Place:
HOTSPOT
Pega Robot Studio provides five rules on how to differentiate between cloneable application objects when using key assignments in automations. The first rule states that an event creates the instance to set the context of a cloneable object. The remaining four rules state the requirements for a key assignment.
In the Answer Area, determine if each rule description requires a key assignment.
Hot Area:
You add a MessageDialog component to an automation. Based on the following image, which option shows the configuration settings that generates the message dialog?
A. Option A
B. Option B
C. Option C
D. Option D
Your log on automation is failing and you cannot proceed because the Submit button is not enabled. After searching the HTML code, you discover that the Submit button is enabled only after the Password field experiences a key press. How do you resolve the automation issue?
A. On the Password field, add an Enabled property and set it to True.
B. On the Password field, add a RaiseEvent method with onkeypress.
C. On the Submit button, add a Disabled property and set it to True.
D. On the Submit button, add a RaiseEvent method with onkeypress.
You are debugging a script component for your project. When the automation executes your script, the intended result does not occur. You suspect that one or more variables within your script are not being set to the proper value. Your version of Pega Robot Studio does not support the use of breakpoints within the script designer.
In what two ways can you debug the script? (Choose two.)
A. Enable Runtime logging and enter a diagnostic message to log the variable values during script execution.
B. Add a breakpoint before calling the script so that you can assign a watch for the variable(s) used within the script.
C. Check with the Support team to upgrade Robotic Automation Studio to the version which contains script debugging.
D. Modify the script so that the variable values are returned in the automation.
Which step allows you to add a Watch to an automation variable?
A. Right-click the execution link (yellow execution line) coming from the variable, and select Add Watch.
B. Right-click the data link (blue propagate line) coming from the variable, and select Add Watch.
C. Right-click the incoming/outgoing execution port (yellow dot) of the variable, and select Add Watch.
D. Right-click the input/output data port (blue dot) of the variable, and select Add Watch.
In a Java application, you click a button to load a grid. The grid loads as a separate process under the Java application. Which property allows you to interrogate the grid?
A. IgnoreMainBrowser
B. TargetPath
C. EnableMatchInProcess
D. HookChildProcesses
A project requirement is to run the solution in multiple environments: Development and Production. Which two items can be added to the two Project Configuration files? (Choose two.)
A. Variable values
B. Citrix Context properties
C. Adapter Text MatchRules
D. Project properties